RAM 3000 Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 14
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
9
MANUAL - SPRAY GUN CLEANERS - UG1000-3000 SERIES REVISION 2007-11
TROUBLESHOOTING CHART
SYMPTOM REASON CORRECTIVE ACTION
• Drain valve closed
• Solvent level too low
• Paint debris in pump
• Blockage in solvent line
After Each Step Below, Turn
Timer. If solvent does not flow,
carry out next step.
Open drain valve (put in verti-
cle position), if not already
open
• Check wash solvent level. Add
solvent if less than 1/2 full.
• Follow Procedure 1, Blocked
Fluid Passage in Diaphragm
Pump.
• Follow Procedure 4, Blocked
Passage in Solvent Line
WASH SOLVENT DOES
NOT FLOW AND PUMP
MAKES A HISSING NOISE
• Water in air line causes
pump to stall
• Follow Procedure 2, Blockage
in Air Passage in Diaphragm
Pump
WASH SOLVENT DOES
NOT FLOW AND PUMP
DOES NOT MAKE A NOISE
• Pump leaks
• Blockage in air passage
• Replace pump
• Follow Procedure 3, Blocked
Passage in Air Line
PUMP DOES NOT STOP
UNLESS TIMER IS TURNED
BY HAND OR AIR IS SHUT
OFF
Defective timer Replace timer
TIMER KNOB SPINS BACK
WHEN TURNED
Defective timer Replace timer
INSIDE WALL OF TANK IS
COATED WITH PAINT EVEN
THOUGH OPERATOR
MAINTAINS TANK
• Solvent lacks cleaning
strength
• Replace solvent with solvent
that is formulated for type of
paint used and for use with
automatic spray gun cleaning
WASH SOLVENT DOES
NOT FLOW AND PUMP
MAKES A PUMPING NOISE