RAM 3000 Manual de usuario Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 14
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
MANUAL - SPRAY GUN CLEANERS - UG1000-3000 SERIES REVISION 2007-11
10
SYMPTOM REASON CORRECTIVE ACTION
CLEANING PROBLEMS
GUNS NOT CLEAN,
PUMP WORKING,
SOLVENT FLOW
NORMAL
Trigger not locked in
open position
Spray gun is not
properly installed
onto nozzle
• Incompatible solvent
Low pressure in air
supply
Plugged jets
After Each Step Below, Turn Timer. If
guns are not clean, carry out next step.
Use Trigger Lock Spring
Re-install with proper adapter
• Replace incompatible solvent with sol-
vent formulated for type of paint used
and for Automatic Spray Gun Cleaners.
Increase air pressure to a minimum of
85 PSI
Remove and clean by blowing air
through the jets. If not successful,
replace.
GUNS NOT CLEAN,
WASH SOLVENT IS
MILKY WHITE
• Wash solvent is con-
taminated with water
• Replace or recycle wash solvent
TROUBLESHOOTING CHART
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14

Comentarios a estos manuales

Sin comentarios